Installation of C125-TINO-MMN Control Unit (Fixed Installation)
DANGER:
By law, only authorized electricians are allowed to install the Control Unit.
Make sure that the power to the stove is disconnected before and during the entire installation.
Do not switch on the power from the electrical panel before you have made sure that the Sensor Unit and the Control Unit are set and ready for a function test.
-
Switch off power to the stove from the electrical
panel.
-
Remove the knock-out lid and pull the wires
through the opening.
- Strip 10 mm from the end of the PE wire and < 10 mm from the ends of the L and N wires.
-
Place the Control Unit onto the screws with the
socket pointing down or to the left.
-
Twist the Control Unit to lock it in place and
tighten the screws.
Make sure that the Control Unit is completely covering the opening on the wall.
-
Connect the wires using one of the following
diagrams. Use a PH2 screwdriver for all connections.
1-Phase wiring
IT-grid wiring
-
To close the cover of the Control Unit, insert the
two teeth into their slots and press the cover against the unit. The lock near
the socket outlet clicks when closed.
Note: To open the cover, press the clip on the cover with an 8mm flat head screwdriver or similar tool.
-
Connect the stove power plug.
Note: Make sure that the plug is properly plugged in.
-
Switch on the power to the stove from the
electrical panel.
- If the installation location is anything other than the default (installation height 50 - 60 cm above the cooktop), set the correct installation zone. See Changing the Installation Zone for more information.