Changing the Installation Zone

To manually change the Sensor Unit sensitivity to match different mounting locations, follow these instructions.

Note:

You can also easily change the settings from the MicroSense® 2 app.

The following instructions are for changing the settings without using the app.

  1. Press and hold the sensor button until you hear two consecutive beeps. Release the button.

    The Sensor Unit confirms with a sound and light, and enters Setup Mode.

  2. Press and hold the sensor button until you hear one beep. Release the button.

    The Sensor Unit confirms with a sound and light, and enters Installation Zone Configuration Mode.

  3. Press the button X times to set the Installation Zone (see the following table).

    The Sensor Unit confirms the selection with the same number of consecutive beeps.

    1 press

    2 presses

    3 presses

    4 presses

    5 presses

    6 presses

    Zone 1

    (Cooker Hood)

    Zone 2

    (Cooker Hood)

    Zone 3

    (Cooker Hood)

    Zone 4

    (Wall)

    Zone 5

    (Wall)

    Zone 6

    (Ceiling)

    45-50 cm

    50-60 cm

    60-80 cm

    45-50 cm

    (Induction)

    50 cm

    160 cm

    See the following figure for the different Installation Zone settings.